Face layer 5 8 in.
1 hour rated roof assembly residential.
Is this possible without using channels and what ul number would i use.
These listings are short summaries to serve as a.
For example shake roofing with a fire retardant treatment rates class b on its own but achieves a class a rating when combined with specified underlying materials such as type 72 roll roofing material.
Thick x 4 ft.
2 hour exterior wall assembly ul design no.
A minimum 1 hour fire resistance rating to prevent embers and hot gases from making contact with the joists rafters or trusses or the underside of the roof decking.
In fact there is no.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
Ul does not appear to list an assembly as described.
1 hour exterior wall assembly ul design no.
Long cup head drywall nails 8 in.
Type x gypsum wallboard applied vertically fastened with 1 7 8 in.
I am looking for a 1 hour roof ceiling assembly for wood truss construction.
Assembly rated class a roof coverings are those that meet class a standards when combined with other elements.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Ibc section 722 6 could be used to calculate up to a 1 hour rating for a wood frame wall floor or roof assembly.
No minimum joist size is given except that it needs to be adequate for structural loads.
I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Use flat horizontal soffits see figure 3 instead of attaching the soffits to the sloped joists which creates sloped soffits.
1 hour wall assembly interek design no.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
Assembly rating 1 hr max loading 1684 lbs.
Ibc table 722 6 2 2 allows 10 minutes for wood floor or roof joists at 16 o c.
Joint tape and compound vinyl or casein dry or premixed joint compound applied to face.