Ibc section 722 6 could be used to calculate up to a 1 hour rating for a wood frame wall floor or roof assembly.
1 hour roof construction.
The section details the procedures for calculating fire resistance of walls floor ceiling and roof ceiling assemblies.
Ibc table 722 6 2 2 allows 10 minutes for wood floor or roof joists at 16 o c.
What you ll eventually learn is that the easiest place to design your own 1 hour assembly is section 721 6 of the international building code.
I am looking for a 1 hour roof ceiling assembly for wood truss construction.
Both are burn through tests and the ultimate roof systems rating is the lowest of the three tests.
During construction there are many opportunities for accidental ignition including welding of steel and the use of torches on modified bituminous roof membranes.
According to the engineered wood association a one hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures and support its full load for at least one hour after the fire begins.
Use flat horizontal soffits see figure 3 instead of attaching the soffits to the sloped joists which creates sloped soffits.
1 hour rating category illustration construction 24 oc min 18 depth resilient channel 16 oc 1 layer 5 8 type c gypsum sheathing min 15 32 ul l546 floor or roof with damper duct fixtures insulation and metal trim note 1 ul l550 pitched roof with duct or damper and insulation note 1 24 oc min 18 depth resilient channel 12 oc.
A minimum 1 hour fire resistance rating to prevent embers and hot gases from making contact with the joists rafters or trusses or the underside of the roof decking.
To the centerline of a street an alley or public way.
Is this possible without using channels and what ul number would i use.
Walls less than 5 feet from the property lot line must be of a listed hour fire1 resistant construction.
One hour roof ceiling assembly.
Wall framing whichever is closer to one of the following.
To the closest interior lot line.
I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control.
Here you can find drawings for our ul fire rated floor assemblies and ul fire rated ceiling assemblies.
Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire rated ceiling assembly.
No minimum joist size is given except that it needs to be adequate for structural loads.
To an imaginary line between two buildings on the lot.
Failure is defined as the point where the roof deck.